Flanged Inverted Bucket Steam Trap for Steam System Management

Product Details
Customization: Available
Media: Gas, Water,Oil,etc.
Standard: GB/T
Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (16)
  • Flanged Inverted Bucket Steam Trap for Steam System Management
  • Flanged Inverted Bucket Steam Trap for Steam System Management
  • Flanged Inverted Bucket Steam Trap for Steam System Management
  • Flanged Inverted Bucket Steam Trap for Steam System Management
  • Flanged Inverted Bucket Steam Trap for Steam System Management
  • Flanged Inverted Bucket Steam Trap for Steam System Management
Find Similar Products
  • Overview
  • Product Description
  • Specification
  • Application
  • Packaging & Shipping
  • Company Profile
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
991-996
Pressure
Ordinary Pressure
Temperature
Ordinary Temperature
Connection
Flange
Material
Cast Iron
Type
Inverted Bucket
Trademark
taian
Origin
Zhejiang
Production Capacity
1000 Piece Per Month

Product Description

Product Description
Flanged Inverted Bucket Steam Trap for Steam System Management
Inverted Bucket Steam Trap
This inverted bucket steam trap features a cobalt-chromium-tungsten alloy sealing surface design, with both the valve seat and spherical core constructed from high-strength wear-resistant alloy material that offers excellent corrosion resistance for long-term stable operation. The precision-ground spherical core achieves perfect matching with the valve seat, delivering exceptional sealing performance without localized wear during operation, significantly extending service life.
The product adopts a unique inverted bucket structure with intelligent vent hole design that effectively prevents steam locking and air binding issues, dramatically improving venting efficiency. Capable of withstanding up to 90% backpressure, its open bucket structure provides outstanding water hammer resistance while maintaining stable performance even under harsh operating conditions.
All internal core components are made of premium stainless steel and integrated onto the valve cover, complemented by an efficient filtration device for quick and easy maintenance. Suitable for condensate drainage in various steam systems, it serves as an ideal choice for industries including petrochemical, power generation, pharmaceutical and food processing, providing reliable and efficient steam trap solutions.
Specification
Flanged Inverted Bucket Steam Trap for Steam System Management
Structural Features and Applications
1.Cobalt-chromium-tungsten alloy sealing surface:long service life.The valve  seat and spherical valve core are made of high-quality alloy,which is wear- resistant,corrosion-resistant  and  durable.
2.The spherical valve core has good sealing performance:The spherical valve core is ground and matched with the valve seat on the mechanical device.  It has good sealing performance,no concentrated wear during operation,   and has a long service life.
3.Good air exhaust performance:the inverted cylinder is equipped with an overflow exhaust hole,which can effectively prevent steam lock and air blockage.
4.Allowed back pressure rate (90%).
5.Water  impact  resistance:The  open  barrel  structure  will  not  be  damaged due to water impact.
6.Easy maintenance:The internal parts are made of stainless steel and are installed on the valve cover.They are also equipped with a filter device,making  daily maintenance easy.
               
Product Configuration Table
Valve Body /Valve Cover
GGG40
Main Valve Seat Vale Core
SS304+STL440C
Bucket/Active Plate/Filter
SS304
One-way Check Valve
SS304
Sealing Gasket
Graphite Composite Gascket/Non-asbestos Pad
Body Material
Ductile  Cast  Iron
Body Nominal Pressure &Max Operating Temp.
Valve   Body   Nominal   Pressure:PN16
Ductile   Cast   Iron   ≤232°C
Size  &Connection
DN15-DN100          Flanged   Connection   PN16
*Can  be  Customize  to  ANSI  150/JIS  10K  or  other  Flanged  Standards
Maximum Operating Pressure Difference
16bar      g
Flanged Inverted Bucket Steam Trap for Steam System Management
Flanged Inverted Bucket Steam Trap for Steam System Management
Maximum Operating Pressure Difference

Flanged Inverted Bucket Steam Trap for Steam System Management
Installation Guidelines
 1.The  correct  installation  and  maintenance  of  this  valve  is  the  only guarantee  for  safety  and  normal  operation.
 2.It should be confimed whether the material,pressure and temperature of the valve body can meet the requirements of the working conditions.
 3.The pipeline must be cleaned and debris removed before installation.
 4.The valve  should  be  installed  horizontally  at the  lowest  point  of the pipe,and  the  flow  direction  should  be  consistent  with  the  direction
       marked  on  the  valve  body.
5.Each  heating  equipment  must  be  equipped with  its  own  drain  valve to  avoid  mutual  interference.
6.Ensuring   that   the   system   can   operating   safely,slowly   open   the valve in front of the trap to gradually heat it up to normal state.
7.Regular   maintenance   is   required  to  ensure  the   normal  operation of  the  steam  trap.
Application
Flanged Inverted Bucket Steam Trap for Steam System Management
Packaging & Shipping
Flanged Inverted Bucket Steam Trap for Steam System Management
Flanged Inverted Bucket Steam Trap for Steam System Management
Flanged Inverted Bucket Steam Trap for Steam System Management
Company Profile

Zhejiang Tai'an Valve Co., Ltd. Is located in the "Hometown of China's Pumps and Valves" on the banks of the Ou River-Oubei Sanqiao Industrial Zone, occupying a prime location facing Wenzhou city across the river and adjacent to national-level scenic destinations such as Yandang Mountain and Nanxi River. Since its establishment, the company has been dedicated to the distribution of high-quality control valves. Our main products include water system valves, check valves, flow and pressure regulating valves, gate valves, butterfly valves, globe valves, ball valves, and control valves, establishing a comprehensive valve solution system that spans industrial, municipal, and construction sectors.
Looking to the future, Tai'an Valve adheres to the operational strategy of "addressing current demands while planning for long-term development. " Through customized service models, we provide global clients with full lifecycle service support. Committed to safeguarding fluid security with meticulous craftsmanship, we persistently strive to deliver value-added experiences that surpass our partners' expectations.
Flanged Inverted Bucket Steam Trap for Steam System Management
Flanged Inverted Bucket Steam Trap for Steam System Management
Certifications
Flanged Inverted Bucket Steam Trap for Steam System Management
Flanged Inverted Bucket Steam Trap for Steam System Management
FAQ

1.Q: Can you provide the assembly drawing for confirmation?
   A: Yes, we can give the relevant drawing within 24 hours.
2.Q: Is the company's product certified?
A: The company has passed ISO certification, each product is produced in strict accordance with the standard process, and must pass the quality inspection before it can be delivered to the customer.
3. Q: Shipping method and payment.
A: We support sea freight. Payment terms support L/C T/T, etc.
4. Q: What is the packaging like?
A: Outer packing wooden cases, foam filled inner packing, to ensure moisture-proof, sealed, strong packing, light weight, easy to transport.
5.Q: How long is your delivery time?
A: Generally it is about 30-45days depending on the order quantity.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier